Rooftop Packaged Units
Airwave rooftop packaged units use R32 refrigerant and provide an integrated commercial heating, cooling and air-handling solution within a factory-assembled package. Available for conventional return-air applications and purpose-designed outside-air duties, equipment can be configured around the project’s required capacity, airflow, external static pressure and operating conditions. Supported by Airwave HVAC Systems Australia from initial selection through technical documentation and commissioning.
Configurations & Fan Technology
Cooling-only and reverse-cycle configurations are available, with inverter compressor options and EC supply-air and condenser-fan options selected around the project requirements.
Airflow, Filtration & Controls
Project-specific airflow and external static pressure, flexible supply-air and return-air arrangements, various filtration options, Modbus HLI as standard and optional BACnet interface. AHRI-certified coils available, subject to the selected configuration.

Designed for 100% Outside Air
Outside-air equipment must be selected around the actual ventilation duty—not treated as a standard comfort-cooling rooftop unit. Airwave outside-air packaged units can be configured to manage high outside-air loads, project-specific leaving-air conditions and the required supply-air volume. Each selection is reviewed around the application and project operating requirements.
Application-Based Selection
Selected around the required outside-air volume, leaving-air condition, external static pressure and project operating requirements.
Ventilation, Filtration & Controls
Configured for fresh-air treatment with project-specific filtration, airflow control and available Modbus or BACnet integration. Dehumidification and condenser reheat options are available to suit project-specific humidity and supply-air requirements.

Key Features
- Cooling-only and reverse-cycle configurations
- Inverter compressor options
- EC supply-air and condenser-fan options
- Economy-cycle fresh-air and return-air dampers as standard
- Epoxy-coated DX and condenser coils as standard
- Optional nano-coated coils for coastal, corrosive and other harsh environments
- Optional C5-M protective paint finish to external panels and structural frame
- Modbus HLI as standard
- Optional BACnet interface
- Various filtration options available to suit project and indoor-air-quality requirements
- Project-specific airflow and external static pressure
- Flexible supply-air and return-air arrangements
- Factory-assembled, wired and tested construction
- Australian technical and project support
Rooftop Packaged Unit Range
Model
Nominal Cooling
Nominal Heating
Nominal Airflow
DPAH0060SD5-IH
16.8 kW
17.3 kW
900 L/s
DPAH0090SD5-IH
20.3 kW
19.7 kW
1,050 L/s
DPAH0120SD5-IH
35.9 kW
37.0 kW
1,800 L/s
55.6 kW
57.0 kW
2,600 L/s
DPAH0240SD5-IH
80.7 kW
79.1 kW
4,400 L/s
DPAH0300SD5-IH
92.5 kW
88.2 kW
4,800 L/s
DPAH0420SA5-IH
112.0 kW
115.0 kW
6,000 L/s
DPAH0480SD5-IH
145.7 kW
142.1 kW
8,100 L/s
DPAH0660SA5-IH
181.0 kW
191.0 kW
9,100 L/s
DPAH0720SD5-IH
202.7 kW
194.8 kW
11,000 L/s
Nominal capacities and airflow values are provided as a general product-range guide. Final equipment performance, configuration and selection are subject to the project design conditions and confirmed technical selection.